Commercial Make-Up Air Unit Service in the GTA
Ventilation equipment service focused on airflow, heating, pressure balance and dependable outdoor-air delivery.
Commercial & industrial HVAC support across the Greater Toronto Area.
Call nowReplacement air that works with the building
Make-up air units introduce conditioned outdoor air to replace air removed by exhaust systems and other building processes. When airflow, heating or controls drift, the result may be pressure imbalance, comfort complaints or ventilation problems. Sensible reviews the unit together with its operating schedule and connected building conditions.
Where this equipment is used
- Commercial kitchens and restaurants
- Warehouses and distribution facilities
- Manufacturing and industrial spaces
- Fitness, retail and high-exhaust buildings

Signs you need make-up air unit repair
- Airflow falling off, or the building going negative when exhaust runs
- Burner or heating-stage faults on cold mornings
- Belt, bearing or motor noise at the unit
- Outdoor-air dampers not opening or closing as commanded
- Cabinet, panel or weather-seal damage after a hard season
- Sensors and schedules calling the unit at times the building does not need it
Signs you need make-up air unit replacement
- Outdoor-air capacity that no longer balances the exhaust it serves
- Heating capacity that cannot temper design outdoor air
- Cabinet or casing condition that repair no longer holds
- Curb, duct or utility interfaces that limit what repair can achieve
- Repairs recurring on the same components across heating seasons
- A kitchen or process change that alters the airflow the unit was sized for
Signs you need make-up air unit preventative maintenance
- Filters, belts, drives and bearings with no scheduled inspection
- Dampers, heating stages and operating controls never reviewed
- Cabinet, panels, weather seals and drainage left unchecked
- Airflow concerns not documented alongside the exhaust they relate to
- No pre-season check before the heating load arrives
- Coordinated exhaust issues raised as separate calls rather than one problem
Frequently asked
That is usually a make-up air balance problem rather than a door or window one. If the unit is not delivering the outdoor air the exhaust is removing, the building goes negative and pulls air through every other opening it can find. The two systems have to be looked at together.
ANSI/ASHRAE/ACCA Standard 180 sets inspection and maintenance tasks at defined frequencies for commercial HVAC equipment. Make-up air units earn a pre-season check before heating, since a burner or damper fault that goes unnoticed in summer shows up on the first cold morning.
Tempering design outdoor air is demanding, so the usual causes are heating stages not all firing, a damper letting in more outdoor air than the burner can temper, or a control sequence that is not staging correctly for the conditions.
Where they serve the same space, yes. Airflow concerns on one side are frequently caused by the other, and treating them as separate service calls tends to mean the same problem gets diagnosed twice.
The work turns on the outdoor-air and exhaust relationship, on heating, cooling and airflow requirements, and on the existing curb, duct, utility and controls connections. Start-up and functional operating checks are part of the job, not a follow-up visit.
Choose the support your equipment needs
Move from equipment information to the right service path without repeating technical detail on every page.
Repairs & Emergency Service
24/7 commercial HVAC support that starts with the fault, documents the findings and explains the recommended repair path.
View related service
Installation & Retrofits
Building-specific installation and retrofit planning that considers equipment condition, load, controls, access and operating constraints.
View related service
Preventive Maintenance
Scheduled, equipment-aware maintenance that helps identify deterioration, support seasonal readiness and improve repair planning.
View related service